HOC - for high temperatures

Standard reference conditions

  • Working pressure: 7 bar (max. 10 bar)
  • Dew point at 7 bar pressure: -40 °C
  • Air inlet temperature 165°C (max. 200°C)
  • Working/regeneration cycle: 180/180 min
  • Standard voltage 400/3/50

The HOC desiccant dryer supplies air with a TRB of -40°C. The thermal energy from the compressed air is used in the drying process, especially for the regeneration of the desiccant. The only additional costs are associated with the operation of the control unit.
The service life and efficiency of the dryer depend on the removal of contaminated elements in the inlet pipe. It is therefore strongly recommended to use coalescing pre-filters at the inlet.
The HOC A version - additionally has a heating system and a control system that is able to respond to the variability of compressed air consumption. The drying mode is then automatically adjusted, ensuring a constant TRB and maximum drying efficiency.

Options

  • Non-standard voltage, 60Hz
  • ANSI flanges
  • Marine surface treatment
  • Remote control
  • Tank insulation
  • Filtration
Type Flow rate (m3/h) Data sheet
HOC 420 420 pdf
HOC 680 680 pdf
HOC 850 850 pdf
HOC 1020 1020 pdf
HOC 1360 1360 pdf
HOC 2040 2040 pdf
HOC 2720 2720 pdf
HOC 3680 3680 pdf