Becker SV - double stage side channel blowers up to 520m3/h

Using "multi-stage" compression, side channel blowers achieve air compression with very low pulsations, which greatly affects the noise level of the device. The perfect design of the impeller with curved blades guarantees optimal efficiency. The separation of the compression chambers on both sides of the impeller allows operation in a single-stage or two-stage version with only one impeller. A suction filter and safety valve can be integrated as an optional accessory in the patented silencer design. Another optional accessory can be the so-called anti-corrosion version, which is suitable for particularly humid operating rooms and sucked media.

Type Volume flow Max. pressure Electromotor Data sheet
  m3/h mbar rel.  kW  
SV 130/2 70 +400  1,10 pdf
SV 200/2 90 +410 1,50 pdf
SV 201/2 90  +420  1,50 pdf
SV 300/2 160 +515  3,00  pdf
SV 400/2 195  +530  4,00 pdf
SV 500/2 260 +480  5,50 pdf
SV 700/2 370 +500  7,50 pdf 
SV 1100/2 520  +500 11  pdf

The blower performance in the table is based on an atmospheric pressure of 1000 mbar abs., a temperature of 20°C and 50Hz.


 SV VASF  gastight VASF 

The integrated frequency converter in the VARIAIR device significantly increases the performance and flexibility of side channel blowers. It is possible to set the exact required performance according to the customer's requirements in both manual and fully automatic mode. The patented intelligent control system keeps the pressure and volume flow constant. The control range of 10-100Hz, i.e. up to 6000 rpm, ensures highly stable performance. The devices are equipped with protective functions, such as temperature and current sensing, and do not need to be equipped with safety valves. The speed control permanently reduces the noise level to the lowest level and, in conjunction with the integrated silencers, no additional noise protection measures are required.

Type Max. Q Max. pressure Data sheet Gastight version
  m3/h mbar rel.    
SV 130/2-400 4kW 25-140 +550 pdf  
SV 201/2-400 4kW 27-175  +560  pdf  
SV 300/2-400 7,5kW 25-320 +570 pdf  
SV 300/-400 7,5kW 40-280     pdf
VASF 1.50/2 0,5kW 2,5-24 +412 pdf pdf
VAFS 1.80/2 1kW 6-40,5 +420 pdf pdf
VASF 1.120/2 1,65kW 16-65 +425 pdf pdf

The blower performance in the table is related to an atmospheric pressure of 1000 mbar abs., a temperature of 20°C and 50Hz.

Volitelné příslušenství